-40%
N2014 Temperature Logger Only (no accessories included)
$ 94.02
- Description
- Size Guide
Description
N2014 Temperature Logger Only (no accessories included)N2014 N2014 Temperature Data LoggerDiligence EV temperature and humidity data loggers feature compact, durable, lightweight design for use in many applications including the food, pharmaceutical and chemical industries and the monitoring of medicines and other sensitive materials in transit or storage. The loggers are also ideal for building services, scientific experiments, production processes and heating, ventilating and air conditioning systems, and countless other applications.Requires 3 Probe Thermocouple Adapter Cable (N2000ADP/K) for use with multiple probes or standard thermocouple connectors.Thermocouple probes can be used in a wide variety of applications and have a variety of options allowing you to choose a temperature probe that works best for you! REQUIRED OPTIONS N2000ADP/K if using with standard Thermocouple probes or if using with multiple probesN2000CRU - One required per computer you are using with the N2014 regardless of the number of loggers being used.Probe(s) Features Four total channels with up to 3 external thermocouple probes Connect up to 3 external type K Thermocouple probes via the N2000ADP/K adapter cable (included) Audible & visual alarm indications LCD display for temperature readings and alarm indication Wide measurement range from -200 °C to +1372 °C (type K) Tough, molded cases, dust and waterproof to IP67 standards Large memory capacity of up to 16000 readings Ability to log over multiple periods Compatibility with the versatile and proven Evolution Windows software Single, multi-function button LED indicators to show active logging and alarm conditions, plus audible alarm warning Long battery life of up to 5 years Two year warranty Requires N2000 Interface Cradle with EVSW Software (See option 1. One required per PC regardless of the number of N2014 loggers you purchase.) Specifications Sensor Type Thermocouple Type T Thermocouple type K Thermistor Measurement Range Type K -200 °C to +1372 °C/-328 °F to +2502 °F Type T -200 °C to +400 °C/-328 °F to +752 °F Thermistor -40 °C to +70 °C/-40 °F to +158 °F Scales °C and °F Resolution (Thermocouple) 0.2 °C up to and including +300 °C 0.5 °C above +300 °C Accuracy at +20 °C, ambient ±0.5 °C +0.3% of reading Accuracy at -20 °C to +40 °C, ambient ±0.5 °C +0.5% of reading Accuracy at -40 °C to +70 °C, ambient ±1.0 °C +1.0% of reading Accuracy at -20 °C to +40 °C ±0.3 °C Thermistor Accuracy at -40 °C to +70 °C ±0.5 °C Thermistor Memory 32K 1 channel 16000 samples 2 channels 8000 samples 3 channels 5300 samples 4 channels 4000 samples Communications Via infra red interface Download Time 3 minutes for 10,000 readings (typical) Logging Frequency Programmable between 1 second and 99 hours Internal Sensor Response time T90 = 15 to 30 minutes in ambient air Ambient Storage -40 °C to +70 °C/-40 °F to +158 °F Logging Start Programmable date and time or manual start from instrument multi-function button Software Windows based software for N2014 Battery Type 1 x AA size 3.6V replaceable lithium battery Battery Life Up to 5 years Case Material ABS Environmental Protection IP67 BS EN 60529 IEC 529 LED Indication Red Alarm Green Logger Active Dimensions Length 88mm/3.5ins (including fixing lug) Width 80mm/3.1ins Depth 35mm/1.4ins
N2014 Temperature Logger Only (no accessories included)
N2014
N2014 Temperature Data Logger
Diligence EV temperature and humidity data loggers feature compact, durable, lightweight design for use in many applications including the food, pharmaceutical and chemical industries and the monitoring of medicines and other sensitive materials in transit or storage. The loggers are also ideal for building services, scientific experiments, production processes and heating, ventilating and air conditioning systems, and countless other applications.
Requires 3 Probe Thermocouple Adapter Cable (N2000ADP/K) for use with multiple probes or standard thermocouple connectors.
Thermocouple probes can be uséd in a wide variety of applications and have a variety of options allowing you to choose a temperature probe that works best for you!
REQUIRED OPTIONS
N2000ADP/K if using with standard Thermocouple probes or if using with multiple probes
N2000CRU - One required per computer you are using with the N2014 regardless of the number of loggers being uséd.
Probe(s)
Features
Four total channels with up to 3 external thermocouple probes
Connect up to 3 external type K Thermocouple probes via the N2000ADP/K adapter cable (included)
Audible & visual alarm indications
LCD display for temperature readings and alarm indication
Wide measurement range from -200 °C to +1372 °C (type K)
Tough, molded cases, dust and waterproof to IP67 standards
Large memory capacity of up to 16000 readings
Ability to log over multiple periods
Compatibility with the versatile and proven Evolution Windows software
Single, multi-function button
LED indicators to show active logging and alarm conditions, plus audible alarm warning
Long battery life of up to 5 years
Two year warranty
Requires N2000 Interface Cradle with EVSW Software (See option 1. One required per PC regardless of the number of N2014 loggers you purchase.)
Specifications
Sensor Type Thermocouple Type T
Thermocouple type K
Thermistor
Measurement Range
Type K -200 °C to +1372 °C/-328 °F to +2502 °F
Type T -200 °C to +400 °C/-328 °F to +752 °F
Thermistor -40 °C to +70 °C/-40 °F to +158 °F
Scales °C and °F
Resolution (Thermocouple) 0.2 °C up to and including +300 °C
0.5 °C above +300 °C
Accuracy at +20 °C, ambient ±0.5 °C +0.3% of reading
Accuracy at -20 °C to +40 °C, ambient ±0.5 °C +0.5% of reading
Accuracy at -40 °C to +70 °C, ambient ±1.0 °C +1.0% of reading
Accuracy at -20 °C to +40 °C ±0.3 °C Thermistor
Accuracy at -40 °C to +70 °C ±0.5 °C Thermistor
Memory 32K
1 channel 16000 samples
2 channels 8000 samples
3 channels 5300 samples
4 channels 4000 samples
Communications Via infra red interface
Download Time 3 minutes for 10,000 readings (typical)
Logging Frequency Programmable between 1 second and 99 hours
Internal Sensor Response time T90 = 15 to 30 minutes in ambient air
Ambient Storage -40 °C to +70 °C/-40 °F to +158 °F
Logging Start Programmable date and time or manual start from instrument multi-function button
Software Windows based software for N2014
Battery Type 1 x AA size 3.6V replaceable lithium battery
Battery Life Up to 5 years
Case Material ABS
Environmental Protection IP67 BS EN 60529 IEC 529
LED Indication
Red Alarm
Green Logger Active
Dimensions
Length 88mm/3.5ins (including fixing lug)
Width 80mm/3.1ins
Depth 35mm/1.4ins
×
Buy now and save!
Tell a friend
Visit store
Watch now
Postage info
Click the Postage tab above the listing description for more info
Click the Postage tab above the listing description for more info!
Additional delivery notes
PICK UP OPTION
Sorry, our items are NOT available for pick-up.
PAYING VIA PAYPAL
We accept PayPal on our all our items so you can shop with confidence.
Simple choose the PayPal option when proceeding through the checkout.
Additional Information
No additional information at this time
Ask seller a question
You might also like
1236-17 Thermometer
1236-70 Espresso Thermometer
1246-01 Pocket Test Thermometer
1246-02 Pocket Test Thermometer
Contact
To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
Ask seller a question
© Tech Instrumentation
Postage
Click the Postage tab above the listing description for more info
Payment
Accepted Payment Methods
PayPal
Returns
Returns are accepted
Items must be returned within 30 days of the auction ending
Buyer will pay for return shipping.
eBay integration
by